8.0 Maintenance Guide
Fluid level should be at 1/8” from the end of the dip stick (check with dip stick cap screwed in). Add
fluid if necessary but avoid overfilling as this could cause leakage when hot. Replace the rear panel
when finished.
The hydraulic fluid should be changed AT LEAST ONCE-A-YEAR or after every 1,000 hours of
operation. NOTE: Failure to change oil when needed can damage seals in the cylinders, pump, and
valves.
Empty the hydraulic tank and refill with 1 gallon of International Standards Organization Viscosity
Grade 100 (ISO VG 100) rust, oxidation, and foam inhibiting hydraulic fluid (Challenge part no.:
S-1991).
NOTE: NEVER use automatic transmission fluid or brake fluid as a substitute for the correct
hydraulic fluid. A table of various manufacturers and their equivalents is listed below.
8.2.1 Recommended Hydraulic Oils
Use one of the recommended oils or an ISO VG 100 Hydraulic Fluid
equivalent only. Oils other than the recommended type will cause seals and O-rings to deteriorate.
Unsafe operating conditions will result.
Oil Name Distributor
Rykon No. 100 AMOCO
Duro AW Oil 465 Arco
AW Machine Oil 100 Chevron
Pacemaker XD No. 100 Citgo
Super Hydraulic 100 Conoco
Nuto H-100 Exxon
Harmony 100 AW Gulf
HO 2A Hydraulic Oil Lubriplate
DTE No. 18 Mobil
Pennzoil AW 100 Pennzoil
Magnus A Oil 215 Phillips
Tellus 100 Shell
Energol HLP 100 Sohio
Industron 100 Std. Oil
Indiana/Boron
Sunvis 851 WR Sun Oil Co.
Rando HD 100 Texaco
Unax AW 100 Union Oil Co.
8.3 Oil and Grease
Turn the power off and disconnect the power cord. Open the front guard (if equipped) and open the
top hood for access. Parts requiring oiling are marked with red paint. See figures Figure 27 through
Figure 34 starting on page 43 for oil and grease locations. Figure 27 through Figure 29 require the
knife and clamp be in the up position. Figure 30 through Figure 34 require the knife and clamp be
down. Wipe off any old or excess grease. Use any brand-name type of grease or light oil to
lubricate. It may be necessary to use the supplied grease brush to access some locations. Note: the
leadscrew may be lubricated with grease or oil. Oil has a tendency to run off and must be lubricated
more frequently; grease tends to collect paper dust and must be cleaned off periodically.